Stay Connected. Manage Your Care.
Access your health information anytime and anywhere, at home or on the go, with MyHealth.
- Message your clinic
- View your lab results
- Schedule your next appointment
- Pay your bill
The MyHealth mobile app from Stanford Health Care puts all your health information at your fingertips and makes managing your health care simple and quick.
Guest Services
24/7
We are available to assist you
whenever you need it. Give us a call at
650-498-3333 or
PHYSICIAN HELPLINE
Have a question? We're here to help! Call 1-866-742-4811
Monday - Friday, 8 a.m. - 5 p.m.
REFER A PATIENT
Fax 650-320-9443
Track your patients' progress and communicate with Stanford providers conveniently and securely.
Abstract
To evaluate the safety and effectiveness of the excimer laser sheath technique for removing embedded inferior vena cava (IVC) filters.Over 12 months, 25 consecutive patients undergoing attempted IVC filter retrieval with a laser-assisted sheath technique were prospectively enrolled into an institutional review board-approved study registry. There were 10 men and 15 women (mean age 50 years, range 20-76 years); 18 (72%) of 25 patients were referred from an outside hospital. Indications for retrieval included symptomatic filter-related acute caval thrombosis (with or without acute pulmonary embolism), chronic IVC occlusion, and bowel penetration. Retrieval was also performed to remove risks from prolonged implantation and potentially to eliminate need for lifelong anticoagulation. After failure of standard methods, controlled photothermal ablation of filter-adherent tissue with a Spectranetics laser sheath and CVX-300 laser system was performed. All patients were evaluated with cavography, and specimens were sent for histologic analysis.Laser-assisted retrieval was successful in 24 (96%) of 25 patients as follows: 11 Günther Tulip (mean 375 days, range 127-882 days), 4 Celect (mean 387 days, range 332-440 days), 2 Option (mean 215 days, range 100-330 days), 4 OPTEASE (mean 387 days, range 71-749 days; 1 failed 188 days), 2 TRAPEASE (mean 871 days, range 187-1,555 days), and 2 Greenfield (mean 12.8 years, range 7.2-18.3 years). There was one (4%) major complication (acute thrombus, treated with thrombolysis), three (12%) minor complications (small extravasation, self-limited), and one adverse event (coagulopathic retroperitoneal hemorrhage) at follow-up (mean 126 days, range 13-302 days). Photothermal ablation of filter-adherent tissue was histologically confirmed in 23 (92%) of 25 patients.The laser-assisted sheath technique appears to be a safe and effective tool for retrieving embedded IVC filters, including permanent types, with implantation ranging from months to > 18 years.
View details for DOI 10.1016/j.jvir.2011.01.459
View details for Web of Science ID 000291414500011
View details for PubMedID 21530309