Hazardous Waste Generator Regulatory Summary
The Resource Conservation and Recovery Act (RCRA) regulations establish basic hazardous waste management standards for persons who produce hazardous waste, called hazardous waste generators. These standards are found in title 40 of the Code of Federal Regulations (CFR) in part 262 and at 40 CFR §261.5. The generator regulations ensure that hazardous waste is appropriately identified and handled safely to protect human health and the environment, while minimizing interference with daily business operations.
The table below provides a summary of requirements for each class of hazardous waste generator. This is not an exhaustive list of all of the requirements for generators and should be used as just a guide. Generators are responsible for all applicable requirements in 40 CFR part 262 for small quantity generators (SQGs) and large quantity generators (LQGs) and 40 CFR §261.5 for conditionally exempt small quantity generators (CESQGs). Additionally, hazardous waste generators should check with their state regulatory agency because certain states have additional or more stringent requirements than the federal government.
Requirement | Conditionally Exempt Small Quantity Generators | Small Quantity Generators | Large Quantity Generators |
---|---|---|---|
Quantity Limits |
≤100 kg/month |
>100 <1,000 kg/month |
≥1,000 kg/month |
EPA ID Number |
Not required |
Required |
Required |
On-Site Accumulation Quantity |
≤1,000 kg |
≤6,000 kg |
No limit |
Accumulation Time Limits |
None |
≤180 days or |
≤90 days |
Accumulation Requirements |
None |
Basic requirements with technical standards for tanks or containers |
Full compliance for management of tanks, containers, drip pads, or containment buildings |
Personnel Training |
Not required |
Basic training required |
Required |
Contingency Plan and Emergency Procedures |
Not required |
Basic plan required |
Full plan required |
Preparedness and Prevention |
Not required |
Required |
Full plan required |
Air Emissions |
Not required |
Not required |
Required |
Land Disposal Restrictions |
Not required |
Required |
Required |
Manifest |
Not required |
Required |
Required |
Waste Minimization |
None |
Good faith effort required |
Program in place required |
Pre-Transport Requirements |
Yes |
Required |
Required |
Biennial Report |
Not required |
Not required |
Required |
Exception and Additional Reporting Provide information on quantities and disposition of wastes upon request |
Not required |
Required |
|
Recordkeeping |
Not required |
Required |
Required |
Facility Type |
Facilities noted in §§261.5(f)(3) and (g)(3) |
RCRA permitted/interim status facility |
RCRA permitted/interim status facility |
Closure |
Not required |
Required - tanks only |
Required - General §§265.111(a) and 265.114 from §262.34(a)(1)(iv) - Unit specific Part 265, subparts I, J, W, and DD |