Laboratory Investigation
Fluoroscopic Registration and Localization for Image-Guided Cranial Neurosurgical Procedures: A Feasibility StudyHenderson J.M. · Hill B.C.Department of Neurosurgery, Stanford University, Stanford, Calif., USA
|
|
Do you have an account?
KAB
Buy a Karger Article Bundle (KAB) and profit from a discount!
If you would like to redeem your KAB credit, please log in.
Save over 20% compared to the individual article price.
Learn more
Subscribe
- Access to all articles of the subscribed year(s) guaranteed for 5 years
- Unlimited re-access via Subscriber Login or MyKarger
- Unrestricted printing, no saving restrictions for personal use
Article / Publication Details
Published online: July 26, 2008
Issue release date: October 2008
Number of Print Pages: 7
Number of Figures: 6
Number of Tables: 1
ISSN: 1011-6125 (Print)
eISSN: 1423-0372 (Online)
For additional information: https://www.karger.com/SFN
Abstract
Background/Aims: Frameless image-guided neurosurgical techniques can achieve high degrees of accuracy when skull-implanted fiducials are used for registration. However, fiducial placement is invasive and uncomfortable for patients. Development of a noninvasive registration method for accurate image-guided functional neurosurgery such as deep brain stimulator placement would therefore be highly desirable. We performed an initial series of experiments using a commercially available fluoroscopic registration package to assess the feasibility of this approach for image-guided functional neurosurgery. We also evaluated the accuracy of landmark placement in the fluoroscopic images using the navigational capability of the software. Methods: A fluoroscopic target was created by etching a hexagonal pattern of 1-mm diameter holes on a copper-clad board (0.0254-mm copper cladding on fiberglass). The target was then mounted in a plastic phantom skull, oriented in a mid-sagittal plane. Five implantable fiducial markers were screwed into the phantom in positions which approximated those commonly used clinically. 1.25-mm CT slices were obtained, uploaded to a Stealthstation neuronavigational system and were displayed using the Fluoromerge software package. Lateral and AP images were generated with 2 approximately orthogonal views of the phantom. Registration was carried out both fluoroscopically and using the implanted fiducials. Targets were localized using both methods and the localization errors recorded. Results: Localization error was less than 1 mm using fiducial-based registration, and between 0.8 and 2.9 mm using fluoroscopic registration. Error varied depending on location within the volume of the phantom. Conclusion: Initial experiments show that fluoroscopic registration is feasible for the performance of frameless functional neurosurgical procedures, although accuracy is still insufficient. Intraoperative verification of lead location was also shown to be feasible in one case.
© 2008 S. Karger AG, Basel
References
- Steinmeier R, Rachinger J, Kaus M, Gansalndt O, Huk W, Fahlbusch R: Factors influencing the application accuracy of neuronavigation systems. Stereotact Funct Neurosurg 2000;75:188–202.
- Dorward NL, Alberti O, Palmer JD, Kitchen ND, Thomas DGT: Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. J Neurosurg 1999;90:160–168.
- Bernardete EA, Leonard MA, Weiner HL: Comparison of frameless stereotactic systems: accuracy, precision, and applications. Neurosurgery 2001;49:1409–1416.
- Helm PA, Eckel TS: Accuracy of registration methods in frameless stereotaxis. Comput Aided Surg 1998;3:51–56.
- Henderson JM: Frameless localization for functional neurosurgical procedures: a preliminary accuracy study. Stereotact Funct Neurosurg 2004;82:135–141.
- Holloway KL, Gaede SE, Starr PA, Rosenow JM, Ramakrishnan V, Henderson JM: Frameless stereotaxy using bone fiducials for deep brain stimulation. J Neurosurg 2005;103:404–413.
-
Maciunas RJ, Fitzpatrick JM, Galloway RL, Allen GS: Beyond stereotaxy: extreme levels of application accuracy are provided by implantable fiducial markers for interactive image guided neurosurgery; in Maciunas RJ (ed): Interactive Image Guided Neurosurgery. Park Ridge, AANS Publications, 1993, pp 259–270.
- Henderson JM, Holloway KL, Gaede SE, Rosenow JM: The application acccuracy of a skull mounted trajectory guide for image-guided functional neurosurgery. Comput Aided Surg 2004;9:155–160.
- Henderson JM, Smith KR, Bucholz RD: An accurate and ergonomic method of registration for image-guided neurosurgery. Comput Med Imaging Graphics 1994;18:273–277.
- Raabe A, Krishnan R, Wolff R, Hermann E, Zimmermann M, Seifert V: Laser surface scanning for patient registration in intracranial image-guided surgery. Neurosurgery 2002;50:797–803.
-
Mascott CR, Sol JC, Bousquet P, Lagarrigue J, Lazorthes Y, Lauwers-Cances V: Quantification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration. Neurosurg 2006;59(1 suppl 1):ONS146–156.
- Vinas FC, Zamorano L, Bucinc R, Li QH, Shamsa F, Jiang Z, Diaz FG: Application accuracy study of semipermanent fiducial system for frameless stereotaxis. Comput Aided Surg 1997;2:257–263.
- Villalobos H, Germano IM: Clinical evaluation of multimodality registration in frameless stereotaxy. Comput Aided Surg 1999;4:45–49.
-
LaRose DA, Bayouth J, Kanade T: Transgraph: interactive intensity-based 2d/3d registration of X-ray and CT data. SPIE Image Process 2000;3979:385–396.
External Resources
- Adler JR, Murphy MJ, Chang SD, Hancock SL: Image-guided robotic radiosurgery. Neurosurgery 1999;44:1299–1306.
- Foley KM, Simon DA, Rampersaud YR: Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 2001;26:347–351.
- Hofstetter R, Slomczykowski M, Sati M, Nolte L-P: Fluoroscopy as an imaging means for computer-assisted surgical navigation. Comput Aided Surg 1999;4:65–76.
- Murphy MJ: An automatic six-degree-of-freedom image restoration algorithm for image-guided frameless stereotaxic radiosurgery. Med Phys 1997;24:857–866.
Article / Publication Details
Published online: July 26, 2008
Issue release date: October 2008
Number of Print Pages: 7
Number of Figures: 6
Number of Tables: 1
ISSN: 1011-6125 (Print)
eISSN: 1423-0372 (Online)
For additional information: https://www.karger.com/SFN
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.