Standard HIMC assays are usually performed on cryopreserved specimens, to allow batching of samples and avoid loss of sensitivity associated with inter-assay variability. An overview of each assay, the associated protocol, and relevant performance data, are found on the above linked pages.  Links to all of our standard lab protocols are also collected here:

Protocol Descriptions for Publications

Luminex – eBioscience/Affymetrix Magnetic bead Kits:  This assay was performed in the Human Immune Monitoring Center at Stanford University.  Human 63-plex or Mouse 38 plex kits were purchased from eBiosciences/Affymetrix and used according to the manufacturer’s recommendations with modifications as described below. Briefly: Beads were added to a 96 well plate and washed in a Biotek ELx405 washer. Samples were added to the plate containing the mixed antibody-linked beads and incubated at room temperature for 1 hour followed by overnight incubation at 4°C with shaking. Cold and Room temperature incubation steps were performed on an orbital shaker at 500-600 rpm. Following the overnight incubation plates were washed in a Biotek ELx405 washer and then biotinylated detection antibody added for 75 minutes at room temperature with shaking. Plate was washed as above and streptavidin-PE was added. After incubation for 30 minutes at room temperature wash was performed as above and reading buffer was added to the wells. Each sample was measured in duplicate. Plates were read using a Luminex 200 instrument with a lower bound of 50 beads per sample per cytokine. Custom assay Control beads by Radix Biosolutions are added to all wells.

Luminex -Polystyrene bead kits:  This assay was performed in the Human Immune Monitoring Center at Stanford University.  Human 51-plex or Mouse 26 plex kits were purchased from Affymetrix and used according to the manufacturer’s recommendations with modifications as described below. Briefly, samples were mixed with antibody-linked polystyrene beads on 96-well filter-bottom plates and incubated at room temperature for 2 h followed by overnight incubation at 4°C. Room temperature incubation steps were performed on an orbital shaker at 500-600 rpm. Plates were vacuum filtered and washed twice with wash buffer, then incubated with biotinylated detection antibody for 2 h at room temperature. Samples were then filtered and washed twice as above and re-suspended in streptavidin-PE. After incubation for 40 minutes at room temperature, two additional vacuum washes were performed, and the samples re-suspended in Reading Buffer. Each sample was measured in duplicate. Plates were read using a Luminex 200 instrument with a lower bound of 100 beads per sample per cytokine. Custom assay Control beads by Radix Biosolutions are added to all wells.

Luminex -EMD Millipore Magnetic kits:  This assay was performed in the Human Immune Monitoring Center at Stanford University.  kits were purchased from EMD Millipore and used according to the manufacturer’s recommendations with modifications as described below. Briefly: samples were mixed with antibody-linked magnetic beads on a 96-well plate and incubated overnight at 4°C with shaking. Cold and Room temperature incubation steps were performed on an orbital shaker at 500-600 rpm. Plates were washed twice with wash buffer in a Biotek ELx405 washer. Following one hour incubation at room temperature with biotinylated detection antibody, streptavidin-PE was added for 30 minutes with shaking. Plates were washed as above and PBS added to wells for reading in the Luminex 200 Instrument with a lower bound of 50-100 beads per sample per cytokine. Each sample was measured in duplicate. Custom assay Control beads by Radix Biosolutions are added to all wells.

MSD Assays:  This assay was performed in the Human Immune Monitoring Center at Stanford University.  Kits were purchased from Meso Scale Discovery and the protocol was followed as recommended. Briefly, antibody-coated 96 well plates were pre-incubated for 30 minutes with 25 uL/well of diluent 2. Sample or 7 point diluted Calibrators were added and plates were sealed and incubated at room temperature for 2.5 h with shaking. Plates were aspirated and washed three times with PBST (PBS+0.05% Tween-20). 25 uL of Sulfo-Tag secondary antibody in diluent 3 was then added and the plate incubated for 2.5 h with shaking. Plates were washed 3 times in PBST as above and 150 uL of 2X reading buffer was added. Plates were read immediately in the Sector Imager 2400. Results were analyzed with Masterplex software by MiraiBio.

For the MSD Hypoxia 3 plex kit, the following changes apply: Plates were pre-blocked with 150 uL of Blocker C for 1hour at room temperature with shaking followed by PBST washes as above. 25 uL per well of diluent 7 was added followed by either sample or calibrators. The Sulfo-Tag antibody was diluted in diluent 8 and the assay was completed as outlined above except that 1X reading buffer was used.

Flow Cytometry Immunophenotyping:  This assay was performed by the Human Immune Monitoring Center at Stanford University.  PBMC were thawed in warm media, washed twice and resuspended at 1x10^7 viable cells/mL. 50 uL cells per well were stained for 45 min at room temperature with the antibodies shown in the table [above] (all reagents from BD Biosciences, San Jose, CA). Cells were washed three times with FACS buffer (PBS supplemented with 2% FBS and 0.1% sodium azide), and resuspended in 200 uL FACS buffer. 100,000 lymphocytes per sample were collected using DIVA 6.0 software on an LSRII flow cytometer (BD Biosciences). Data analysis was performed using FlowJo v9.3 by gating on live cells based on forward versus side scatter profiles, then on singlets using forward scatter area versus height, followed by cell subset-specific gating.

Phosphoepitope Flow Cytometry (Cytokine stimulation, pSTAT readouts):  This assay was performed by the Human Immune Monitoring Center at Stanford University.  PBMC were thawed in warm media, washed twice and resuspended at 0.5x10^6 viable cells/mL. 200 uL of cells were plated per well in 96-well deep-well plates. After resting for 1 hour at 37C, cells were stimulated by adding 50 ul of cytokine (IFNa, IFNg, IL-6, IL-7, IL-10, IL-2, or IL-21) and incubated at 37°C for 15 minutes. The PBMCs were then fixed with paraformaldeyde, permeableized with methanol, and kept at -80C overnight. Each well was bar-coded using a combination of Pacific Orange and Alexa-750 dyes (Invitrogen, Carlsbad, CA) and pooled in tubes. The cells were washed with FACS buffer (PBS supplemented with 2% FBS and 0.1% soium azide), and stained with the following antibodies (all from BD Biosciences, San Jose, CA): CD3 Pacific Blue, CD4 PerCP-Cy5.5, CD20 PerCp-Cy5.5, CD33 PE-Cy7, CD45RA Qdot 605, pSTAT-1 AlexaFluor488, pSTAT-3 AlexaFluor647, pSTAT-5 PE. The samples were then washed and resuspended in FACS buffer. 100,000 cells per stimulation condition were collected using DIVA 6.0 software on an LSRII flow cytometer (BD Biosciences). Data analysis was performed using FlowJo v9.3 by gating on live cells based on forward versus side scatter profiles, then on singlets using forward scatter area versus height, followed by cell subset-specific gating.

Intracellular cytokine staining:  This assay was performed by the Human Immune Monitoring Center at Stanford University.  PBMC were thawed in warm media, washed twice and resuspended at 1x10^7 viable cells/mL. 200 uL of cells were plated per well in 96-well V-bottom plates. After overnight rest at 37C, activation reagents [specify here] + 10 ug/mL brefeldin A (Sigma, St. Louis, MO) were added and the cells incubated for 6 hours at 37°C. EDTA was then added to 15 mM final concentration, and the cells washed with PBS. They were then stained with Red LIVE/DEAD cell viability dye (Invitrogen, Carlsbad, CA) according to the manufacturer's instructions. After washing with FACS buffer (PBS supplemented with 2% FBS and 0.1% sodium azide), cells were resuspended in 200 uL of 1x BD FACS Lysing Solution (BD Biosciences), and the cells incubated for 10 min at room temperature. They were then centrifuged at 500 x G for 5 min, and resuspended in 200 uL of 1x BD FACS Permeabilizing Solution 2 (BD Biosciences). After 10 min at room temperature, the cells were washed twice with FACS buffer, and resuspended in 200 uL FACS buffer. Staining with cytokine-specific antibodies [insert list here] was then performed for 1 h at room temperature, followed by two additional washes with FACS buffer. 100,000 CD3+ cells per sample were collected using DIVA 6.0 software on an LSRII flow cytometer (BD Biosciences). Data analysis was performed using FlowJo v9.3 by gating on live cells based on forward versus side scatter profiles, then on singlets using forward scatter area versus height, followed by dead cell exclusion using Red LIVE/DEAD viability dye, and then cell subset-specific gating.

Activation reagents: PMA, PHA, Ionomycin (Sigma, St. Louis, MO); anti-CD3/CD28 antibodies (Invitrogen, Carlsbad, CA); CMV pp65 + IE-1 peptide mix (JPT, Berlin, Germany).

Standard Ab cocktail: CD3 V500, CD8 V450, CD4 PerCP Cy5.5, IFNgamma FITC, IL17 PE, IL2 PE Cy7, TNF AlexaFluor 700, IL-22 APC.

CyTOF Immunophenotyping:  This assay was performed in the Human Immune Monitoring Center at Stanford University.  PBMCs were thawed in warm media, washed twice, resuspended in CyFACS buffer (PBS supplemented with 2% BSA, 2 mM EDTA, and 0.1% soium azide), and viable cells were counted by Vicell. Cells were added to a V-bottom microtiter plate at 1.5 million viable cells/well and washed once by pelleting and resuspension in fresh CyFACS buffer. The cells were stained for 60 min on ice with 50 uL of the following antibody-polymer conjugate cocktail: [insert Ab list here]. All antibodies were from purified unconjugated, carrier-protein-free stocks from BD Biosciences, Biolegend, or R&D Systems. The polymer and metal isotopes were from DVS Sciences. The cells were washed twice by pelleting and resuspension with 250 uL FACS buffer. The cells were resuspended in 100 uL PBS buffer containing 2 ug/mL Live-Dead (DOTA-maleimide (Macrocyclics) containing natural-abundance indium). The cells were washed twice by pelleting and resuspension with 250 uL PBS. The cells were resuspended in 100 uL 2% PFA in PBS and placed at 4C overnight. The next day, the cells were pelleted and washed by resuspension in fresh PBS. The cells were resuspended in 100 uL eBiosciences permeabilization buffer (1x in PBS) and placed on ice for 45 min before washing twice with 250 uL PBS. If intracellular staining was performed, the cells were resuspended in 50 uL antibody cocktail in CyFACS for 1 hour on ice before washing twice in CyFACS. The cells were resuspended in 100 uL iridium-containing DNA intercalator (1:2000 dilution in PBS; DVS Sciences) and incubated at room temperature for 20 min. The cells were washed twice in 250 uL MilliQ water. The cells were diluted in a total volume of 700 uL in MilliQ water before injection into the CyTOF (DVS Sciences). Data analysis was performed using FlowJo v9.3 (CyTOF settings) by gating on intact cells based on the iridium isotopes from the intercalator, then on singlets by Ir191 vs cell length, then on live cells (Indium-LiveDead minus population), followed by cell subset-specific gating.

RNA extraction and microarray--whole blood (PAXgene), Illumina microarray:  Work was performed by the Human Immune Monitoring Center at Stanford University.  RNA sampling and extraction: Blood was collected directly into PAXgene Blood RNA Tube (BD PreAnalytix) using a 21-gauge butterfly needle and catheter so that tubes could be held low and vertical to maintain the vacuum on top of the stabilization solution. Tubes were inverted 10 times. Each tube drew a maximum of 2.5 ml of blood. Samples were incubated in collection tubes at room temperature then stored at -80C within 4h. Total RNA was isolated according to the manufacturer’s Instructions by using a PAXgene RNA blood kit (Qiagen).The entire procedure was carried out at room temperature with the QIAcube automated robot (Qiagen) . Total RNA yield was assessed using the Thermo Scientific NanoDrop 1000
micro-volume spectrophotometer (absorbance at 260 nm and the ratio of 260/280 and 260/230). RNA integrity was assessed using the Agilent’s Bioanalyzer NANO Lab-on-Chip instrument (Agilent).

Microarray processing and analysis: Biotinylated, amplified antisense complementary RNA (cRNA) targets were prepared from 200 to 250 ng of the total RNA using the Illumina RNA amplification kit (Applied Biosystems/Ambion). Seven hundred and fifty nanograms of labeled cRNA was hybridized overnight to Illumina Human HT-12 V3 BeadChip arrays (Illumina), which contained >48,000 probes. The arrays were then washed, blocked, stained and scanned on an Illumina BeadStation 500 following the manufacturer’s protocols. BeadStudio/GenomeStudio software (Illumina) was used to generate signal intensity values from the scans. For normalization, the software was used to subtract background and scale average signal intensity for each sample to the global average signal intensity for all samples. A gene expression analysis software program, GeneSpring GX version 7.3.1 (Agilent Technologies), was used to perform further normalization. Transcripts meeting the filtering criteria were subjected to hierarchical clustering using GeneSpring.

RNA extraction and microarray--PBMC or sorted cells, Agilent microarray:  Work was performed by the Human Immune Monitoring Center at Stanford University.  RNA sampling and extraction: PBMC or sorted cell populations (< 1x10^7 viable cells) were collected in 1ml TRIzol (Invitrogen) and stored at -80c until use). Total RNA was isolated according to the TRIzol protocol (Invitrogen) or RNeasy Mini Kit (Qiagen). For using the RNeasy Mini Kit, the entire procedure was carried out at room temperature with the QIAcube automated robot (Qiagen) . Total RNA yield was assessed using the Thermo Scientific NanoDrop 1000 micro-volume spectrophotometer (absorbance at 260 nm and the ratio of 260/280 and 260/230). RNA integrity was assessed using the Agilent’s Bioanalyzer NANO Lab-on-Chip instrument (Agilent).

Microarray processing and analysis: Cy3 and/or Cy5 labeled, amplified antisense complementary RNA (cRNA) targets were prepared from 20 to 500 ng of the total RNA using the QuickAmp Labeling kit or the Low Input Quick Amp Labeling Kit (Agilent). 850 ug of labeled cRNA was hybridized overnight to Agilent Whole Human Genome 4 x 44 K slides, which contain 44,000 probes, including 19,596 Entrez Gene RNAs; or to SurePrint G3 Human Gene Expression 8x60k slides, which contain 60,000 probes, including 27,958 Entrez Gene RNAs and 7,419 lincRNAs. The arrays were then washed, blocked, stained and scanned on the Agilent microarray scanner following the manufacturer’s protocols. Data were extracted using Agilent Feature Extraction Software. Microarray normalization was performed by GeneSpring GX 11.0 software. Further statistical and bioinformatic analyses were done with Ingenuity Pathway Analysis software (Ingenuity Systems).Transcripts meeting the filtering criteria were subjected to hierarchical clustering using GeneSpring.

Biomark Microfluidic qPCR Array:  This assay was performed by the Human Immune Monitoring Center at Stanford University.  For 10-50 ng total RNA, reverse transcription of the RNA to cDNA was performed at 50°C for 15 minutes using the High Capacity Reverse Transcription kit (ABI). For cell samples, RT was performed directly on a 96-well PCR plate (ABI) containing lysis buffer (Invitrogen) by using SuperScript III One-Step RT-PCR System with PlatinumTaq (CellDirect kit, Invitrogen). PreAmp was performed on a thermocycler using the TaqMan PreAmp Master Mix Kit (Invitrogen) added to cDNA and pooled Taqman assays. RT enzyme was inactivated and the Taq polymerase reaction was started by bringing the sample to 95 °C for 2 minutes. The cDNA was preamplified by denaturing for 10 (total RNA) to 18 (single cell) cycles at 95°C for 15 seconds, annealing at 60°C for 4 minutes. The resulting cDNA product was diluted 1:2 with 1x TE buffer (Invitrogen). 2X Applied Biosystems Taqman Master Mix , Fluidigm Sample Loading Reagent, and preamplified cDNA were mixed and loaded into the 48.48 Dynamic Array (Fluidigm) sample inlets, followed by loading 10X assays into the assay inlets. Manufacturer’s instructions for chip priming, pipetting, mixing, and loading onto the BioMark system were followed. Real-time PCR was carried out with the following conditions: 10 min at 95°C, followed by 50 cycles of 15 sec at 95°C and 1 min at 60°C. Data was analyzed using Fluidigm software. All reactions were performed in duplicate or triplicate, and Ct values were normalized to the GAPDH or 18S positive control.